XP POWER Industrial Partner

ECS100 - XP Power ECS100 Series Power Supply. Input Voltage: 80-264 VAC...

larger image

Request Quote
For Price
Part Number:
ECS100
Model Number:
ECS100
Make:
XP POWER
Lead Time:
Available
Qty In Stock:
Available

XP Power ECS100 Series Power Supply. Input Voltage: 80-264 VAC | Input Frequency: 47-400 Hz | Output Voltage: 12-48 VDC | Operating Temperature: -20 to 70 C | Operating Altitude: 3000 m Simple Type: Power Supply

The ECS100 Series has been designed to minimize the no load power consumption (<0.5 W) and maximize efficiency in order to facilitate equipment design to the latest environmental legislation. Approved for Class I and Class II applications, the ECS100 range of single output AC-DC, 100 W power supplies feature high power density in an industry standard 2 x 4" (51.0 mm x 102.0 mm) footprint. The 1.20" (31.0 mm) high, 1U compatible high-density power supplies meet EN55022 Level B conducted emissions with low earth leakage currents of 100 µA at 115 VAC or 215 µA at 230 VAC. Making these switchers ideal for industrial, IT and medical applications. The ECS100 series has single output versions from 12 V to 48 VDC, adjustable by ±10%. They are dual-fused for compliance with IEC60601-1 and efficiency is 88% typical, so minimal excess heat is generated. The ECS100 require only 10 CFM of cooling to delivers a full 100 W of power up to +50 °C and operates at up to +70 °C with derating or equally supply 80 W when convection- cooled up to +50 °C with operation to +70 °C with derating.

Download the datasheet (PDF)

For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.

Features

  • 80/100 W - Convection/Forced-cooled Ratings
  • Class I & Class II Construction
  • Green Mode, <0.5 W Standby Power
  • Industry Standard 2” x 4” Package
  • IT & Medical Safety Approvals
  • Low Leakage Current

Specifications

    General
  • Conducted Immunity: EN61000-4-6, level 3 Perf Criteria A
  • Cooling: Convection & fan cooled ratings (see tables)
  • Dips & Interruptions: EN61000-4-11, 30% 10 ms, 60% 100 ms, 100%5000 ms, Perf Criteria A, B, B, EN60601-1-2, 30% 500 ms, 60% 100 ms, 100%10 ms, 100% 5000 ms, Perf Criteria A, A, A, B - 230 VAC. Consult longform datasheet for 115 V operation
  • Drift: ±0.2% after 20 min warm up
  • Earth Leakage Current: 230 µA at 264 VAC/60 Hz max.
  • Efficiency: 88% typical
  • EFT/Burst: EN61000-4-4, level 3 Perf Criteria A
  • Emissions: EN55022 level B conducted EN55022 level A radiated
  • Equipment Protection Class: Class I and Class II
  • Harmonic Currents: EN61000-3-2, class A
  • Hold Up Time: 16/75 ms min at 115/230 VAC
  • Initial Set Accuracy: ±1%
  • Input Current: 1.5 A typical at 115 VAC, full load, 0.9 A typical at 230 VAC, full load
  • Input Frequency: 47-400 Hz (See note 1)
  • Input Protection: Internal T5 A/250 V fuse in line and neutral
  • Input Voltage: 80-264 VAC (120-370 VDC), derate output power <90 VAC, see derating curve
  • Inrush Current: 40 A max at 230 VAC, cold start 25 ºC
  • Isolation: 4000 VAC Input to Output, 1500 VAC Input to Ground, 500 VDC Output to Ground
  • Line Regulation: ±0.5% max
  • Load Regulation: ±1%
  • Low Voltage PSU EMC: EN61204-3, high severity level as below
  • Minimum Load: No minimum load required
  • MTBF: 834 kHrs to MIL-HDBK-217F at 25 ºC, GB 1245 kHrs to Telecordia SR-332 at 25 ºC, GB
  • No Load Input Power: <0.5 W
  • Operating Altitude: 3000 m
  • Operating Humidity: 95% RH, non-condensing
  • Operating Temperature: -20 °C to +70 °C derate linearly from +50 °C at 2.5%/°C to 50% load at +70 °C.
  • Output Voltage: 12-48 VDC (see tables)
  • Output Voltage Trim: ±10%
  • Over/Undershoot: 5% typical
  • Overload Protection: 110-150%
  • Overvoltage Protection: 115-140% Vnom, recycle input to reset
  • Power Density: 10 W/in3
  • Power Factor: EN61000-3-2, class A
  • Radiated Immunity: EN61000-4-3, level 3 Perf Criteria A
  • Ripple & Noise: 1% pk-pk V1, 20 MHz bandwidth
  • Safety Approvals: IEC60950-1 CB report, CSA 22.2 No. 60950-1, UL60950-1, TUV EN60950-1 IEC60601-1 CB report, CSA 22.2 No. 60601-1, UL60601-1, TUV 60601-1
  • Shock: 30 g pk, half sine, 6 axes
  • Short Circuit Protection: Continuous trip and restart (Hiccup mode)
  • Start Up Delay: 1stypical
  • Start Up Rise Time: 50 ms
  • Storage Temperature: -40 °C to +85 °C
  • Surge: EN61000-4-5, installation class 3 Perf Criteria A
  • Switching Frequency: 65 KHz typical
  • Temperature Coefficient: 0.05%/°C
  • Transient Response: 4% max. deviation, recovery to within 1% in 500 µs for a 50-75-50% load change
  • Vibration: 2grms,5Hzto500Hz,3axes
  • Voltage Flicker: EN61000-3-3

 

Applications

  • None Available

Aliases