XP POWER Industrial Partner

ECM60UD21 - XP Power ECM60UD21 Power Supply, 90-264VAC, 5V, 12V, 60W Simple...

larger image

Request Quote
For Price
Part Number:
ECM60UD21
Model Number:
ECM60UD21
Make:
XP POWER
Lead Time:
Available
Qty In Stock:
Available

XP Power ECM60UD21 Power Supply, 90-264VAC, 5V, 12V, 60W Simple Type: TBD

Download the datasheet (PDF)

For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.

Features

  • 3 Year Warranty
  • Class I and II Construction
  • Compact Size
  • Convection-cooled
  • DC Input Version Available (DCM Series)
  • IT & Medical Approvals
  • PoE Isolation Version Available (POE Series)

Specifications

    General
  • Cooling: Convection & fan-cooled ratings
  • Cross Regulation: 2% on ECM40/60 only
  • Earth Leakage Current: <125 µA at 115 VAC/60 Hz; <210 µA at 230 VAC/50 Hz
  • Efficiency: 80-85% depending on model
  • Hold Up Time: 16/75 ms min at 115/230 VAC
  • Initial Set Accuracy: ±1.0% V1, ±5% V2, V3 & V4
  • Input Current: 40 W: 0.4 A max at 230 VAC; 60 W: 0.6 A max at 230 VAC; 100 W: 0.9 A max at 230 VAC
  • Input Frequency: 47-63 Hz; 440 Hz
  • Input Protection: Internal T3.15 A, 250 V fuse in line and neutral
  • Input Voltage: 90-264 VAC (120-370 VDC)
  • Inrush Current: 40 A max at 230 VAC
  • Isolation: 4000 VAC Input to Output 2 x MOPP; ECM100 single output models, 1 x MOPP; ECM100 multi output and all ECM40/60 models, 1500 VAC Input to Ground 1 x MOPP, 500 VAC Output to Ground
  • Line Regulation: ±0.5%
  • Load Regulation: ±1% single output models; ±3% V1, ±5% V2 & V3 ECM40/60 multi-output models. ±1% V1 & V2, ±5% V3 & V4 ECM100
  • MTBF: 600 kHrs to MIL-HDBK-217F at 25 °C, GB
  • Operating Altitude: 3000 m
  • Operating Humidity: 95% RH, non-condensing
  • Operating Temperature: 0 °C to +70 °C
  • Output Voltage Trim: ±5% on 3.3 V & 5 V versions, ±10% on other single output models and V1 of multi-output models
  • Over/Undershoot: None at turn on/off
  • Overload Protection: 110-150% on primary power limit, auto recovery
  • Overvoltage Protection: 115-135% Vnom, recycle input to reset
  • Peak Load: 120% for 100 ms ECM40/60
  • Power Density: 40 W: 4.2 W/In3; 60 W: 6.3 W/In3; 100 W: 7.4 W/In3
  • Power Factor: EN61000-3-2
  • Ripple & Noise: 1% pk-pk, 20 MHz bandwidth
  • Shock: 30 g pk, half sine, 6 axes
  • Short Circuit Protection: Trip and restart (hiccup mode)
  • Start Up Delay: 1.5 s max
  • Start Up Rise Time: 10 ms max
  • Storage Temperature: -40 °C to +85 °C
  • Switching Frequency: 70 kHz typical
  • Temperature Coefficient: 0.05%/°C
  • Transient Response: 4% max. deviation, recovery to within 1% in 500 µs for a 25% load change
  • Vibration: 2 g rms, 5 Hz to 500 Hz, 3 axes

 

Applications

  • None Available

Aliases