XP POWER Industrial Partner

HUP15A-12 - XP Power HUP15A-12 12V / 1.25A Max 15W Switching Desktop...

larger image

Request Quote
For Price
Part Number:
HUP15A-12
Model Number:
HUP15A-12
Make:
XP POWER
Lead Time:
Available
Qty In Stock:
Available

XP Power HUP15A-12 12V / 1.25A Max 15W Switching Desktop Power Supply Adapter Simple Type: Power Supply

The HUP15 Series of AC-DC switching power supplies provide 15 watts of continuous output power. They are enclosed in a 94V-0 rated polyphenylene oxide case with an IEC 320 inlet connector to mate with an interchangable cord for worldwide use. All models meet CISPR Class B and FCC Class B emission limits, and are approved to UL, CSA, and TUV safety standards.

Download the datasheet (PDF)

For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.

Features

  • 100% Burn-in
  • Approved to UL, CSA, and TUV safety standards CE Mark
  • Built-in EMI filter
  • Input surge current protection
  • Short circuit protection
  • Small size, light weight
  • Wide input voltage 90-264 VAC

Specifications

    General
  • Efficiency: 60% min at 15W output
  • EMI requirements: Meets conducted and radiated limits of:FCC20780 Level B,CISPR 22 Class B
  • Hold-up time: 5msec minimum
  • Input current: 0.4A maximum
  • Input frequency: 47 to 63 Hz
  • Input voltage: 90 to 264 VAC
  • Inrush current: 15 amps@115 VAC, or 30 amps@230 VAC at 25°C cold start
  • Insulation resistance: 50 Mohm min. from output to ground
  • Line regulation: ±0.5% maximum at full load
  • MTBF: 100,000 hours minimum at full load at 25°C ambient
  • Operating temperature: 0°C to +70°C
  • Output power range: 0 to 15 Watts
  • Overcurrent protection: All outputs protected to short circuit conditions
  • Ripple and noise: 1% peak to peak maximum
  • Safety ground leakage current: 0.75mA max. @ 240VAC 50Hz
  • Safety requirements: Approved to:UL 1950, CSA C22.2 No. 234, EN60950
  • Storage temperature: –40°C to +85°C
  • Temperature coefficient: All outputs ±0.04%/°C maximum
  • Transient response: Maximum excursion of 4% or better on all models. Recovers to 1% of final value within 500us after a 25% step load change.
  • Withstand voltage: 3000 VAC from input to output, 1500 VAC from input to ground, 500 VAC from output to ground

 

Applications

  • None Available

Aliases