HUL200-13 - XP Power HUL200-13 200W AC/DC HUL200 Series Compact Size U-Frame...
Request Quote
For Price
- Part Number:
- HUL200-13
- Model Number:
- HUL200-13
- Make:
- XP POWER
- Lead Time:
- Available
- Qty In Stock:
- Available
XP Power HUL200-13 200W AC/DC HUL200 Series Compact Size U-Frame Power Supply, 15.0 V / 0.5 A ( 13.3 A Max @ 18.7 CFM) Simple Type: Power Supply
For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.
Features
- Compact Size, Low Profile
- Convection-Cooled Ratings
- International Safety Approvals
- Power Fail Detect
- Remote On/Off
- Single and Multiple Outputs
- Up to 5.85 W/in3 Power Density
Specifications
- Conducted Immunity: EN61000-4-6, 10 V Perf Criteria B
- Dips & Interruptions: EN61000-4-11, 30% 10 ms, 70% 100 ms, 95% 5000 ms, Perf Criteria A, B, B
- Earth Leakage Current: < 1.5 mA at 230 VAC / 50 Hz
- Efficiency: 80% typical
- EFT/Burst: EN61000-4-4, level 3 Perf Criteria B
- Emissions: EN55022 and FCC, level B (level A - 300 W) conducted
- ESD Immunity: EN61000-4-2, level 4 Perf Criteria B
- Fan Output: 12 V, 300 mA
- Harmonic Currents: EN61000-3-2, class B
- Hold Up Time: >15 ms at 115 VAC
- Humidity: Operating:5-90% RH, non-condensing
- Initial Set Accuracy: ±1% max for single/main output, ±5% for auxiliary outputs
- Input Current: 5.0 A max at 115 VAC, 2.5 A max at 230 VAC
- Input Frequency: 47-63 Hz
- Input Voltage: 90-132 VAC, 180-264 VAC (auto-ranging)
- Inrush Current: 35 A at 115 VAC, 70 A max at 264 VAC, +25 ºC cold start
- Isolation: 3000 VAC Input to Output, 1500 VAC Input to Ground, 500 VAC Output to Ground
- MTBF: 100 kHrs per MIL-HDBK-217F
- Operating Altitude: 3000 m
- Output Voltage Trim: ±5% on output 1
- Over/Undershoot: <5% max
- Overload Protection: 110-135% of total power, auto recovery
- Overtemperature Protection: Shuts down when ambient temperature exceeds +85 °C, auto recovery
- Overvoltage Protection: 130% on output 1 only, recycle input to reset
- Power Density: 5.85 W/In3
- Power Factor: Passive PFC, meets EN6100-3-2, -3
- Power Fail Detect: On equals Logic high 100-500 ms after outputs with regulation; Fail equals Logic low at least 1 ms prior to loss of output
- Radiated Immunity: EN61000-4-3, level 3 Perf Criteria B
- Remote On/Off: On equals Logic High or Open; Off equals Logic Low or Short
- Ripple & Noise: 1% pk-pk (50 mV max for 3.3 V output)
- Safety Approvals: EN60950, UL60950, CSA22.2 No. 950 per cUL, CE Mark
- Short Circuit Protection: Trip and restart (Hiccup mode)
- Start Up Delay: 1 s max
- StartUp Rise Time: 20 ms max
- Surge: EN61000-4-5, level 3 Perf Criteria B
- Switching Frequency: 42 kHz typical
- Temperature: Operating:0°C to +60 °C, derate linearly from 100% at +40 °C to 50% at +60 °C; Storage:-20 °C to +85 °C
- Temperature Coefficient: ±0.1% / °C
- Total Regulation: ±1% max for single output models, ±5% max for multiple output models
- Transient Response: 5% max. deviation, recovery to within 1% in 500 µsfor a 50% load change
- Vibration: 5 Hz to 50 kHz, 7.35 m/s2 on 3 axis
- Voltage Flicker: EN61000-3-3 amendments 1 & 2
Applications
- None Available
Aliases