XP POWER Industrial Partner

HUL200-12 - XP Power HUL200-10-12 200W AC/DC HUL200 Series Compact Size U-Frame...

larger image

Request Quote
For Price
Part Number:
HUL200-12
Model Number:
HUL200-12
Make:
XP POWER
Lead Time:
Available
Qty In Stock:
Available

XP Power HUL200-10-12 200W AC/DC HUL200 Series Compact Size U-Frame Power Supply, 5.0 V / 0.5 A ( 40.0 A Max @ 18.7 CFM) Simple Type: Power Supply

Download the datasheet (PDF)

For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.

Features

  • Compact Size, Low Profile
  • Convection-Cooled Ratings
  • International Safety Approvals
  • Power Fail Detect
  • Remote On/Off
  • Single and Multiple Outputs
  • Up to 5.85 W/in3 Power Density

Specifications

    General
  • Conducted Immunity: EN61000-4-6, 10 V Perf Criteria B
  • Dips & Interruptions: EN61000-4-11, 30% 10 ms, 70% 100 ms, 95% 5000 ms, Perf Criteria A, B, B
  • Earth Leakage Current: < 1.5 mA at 230 VAC / 50 Hz
  • Efficiency: 80% typical
  • EFT/Burst: EN61000-4-4, level 3 Perf Criteria B
  • Emissions: EN55022 and FCC, level B (level A - 300 W) conducted
  • ESD Immunity: EN61000-4-2, level 4 Perf Criteria B
  • Fan Output: 12 V, 300 mA
  • Harmonic Currents: EN61000-3-2, class B
  • Hold Up Time: >15 ms at 115 VAC
  • Humidity: Operating:5-90% RH, non-condensing
  • Initial Set Accuracy: ±1% max for single/main output, ±5% for auxiliary outputs
  • Input Current: 5.0 A max at 115 VAC, 2.5 A max at 230 VAC
  • Input Frequency: 47-63 Hz
  • Input Voltage: 90-132 VAC, 180-264 VAC (auto-ranging)
  • Inrush Current: 35 A at 115 VAC, 70 A max at 264 VAC, +25 ºC cold start
  • Isolation: 3000 VAC Input to Output, 1500 VAC Input to Ground, 500 VAC Output to Ground
  • MTBF: 100 kHrs per MIL-HDBK-217F
  • Operating Altitude: 3000 m
  • Output Voltage Trim: ±5% on output 1
  • Over/Undershoot: <5% max
  • Overload Protection: 110-135% of total power, auto recovery
  • Overtemperature Protection: Shuts down when ambient temperature exceeds +85 °C, auto recovery
  • Overvoltage Protection: 130% on output 1 only, recycle input to reset
  • Power Density: 5.85 W/In3
  • Power Factor: Passive PFC, meets EN6100-3-2, -3
  • Power Fail Detect: On equals Logic high 100-500 ms after outputs with regulation; Fail equals Logic low at least 1 ms prior to loss of output
  • Radiated Immunity: EN61000-4-3, level 3 Perf Criteria B
  • Remote On/Off: On equals Logic High or Open; Off equals Logic Low or Short
  • Ripple & Noise: 1% pk-pk (50 mV max for 3.3 V output)
  • Safety Approvals: EN60950, UL60950, CSA22.2 No. 950 per cUL, CE Mark
  • Short Circuit Protection: Trip and restart (Hiccup mode)
  • Start Up Delay: 1 s max
  • StartUp Rise Time: 20 ms max
  • Surge: EN61000-4-5, level 3 Perf Criteria B
  • Switching Frequency: 42 kHz typical
  • Temperature: Operating:0°C to +60 °C, derate linearly from 100% at +40 °C to 50% at +60 °C; Storage:-20 °C to +85 °C
  • Temperature Coefficient: ±0.1% / °C
  • Total Regulation: ±1% max for single output models, ±5% max for multiple output models
  • Transient Response: 5% max. deviation, recovery to within 1% in 500 µsfor a 50% load change
  • Vibration: 5 Hz to 50 kHz, 7.35 m/s2 on 3 axis
  • Voltage Flicker: EN61000-3-3 amendments 1 & 2

 

Applications

  • None Available

Aliases

  • None Available