XP Power BCC400PS24 Power Supply - 408W AC/DC Industrial Type, Wide Operating Temperature Range Simple Type: Power Supply

Download the datasheet (PDF)

For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.

Features

  • 3 Year Warranty
  • Baseplate-cooled
  • ETSI, EMC and Environmental Compliant
  • Low Temperature Option
  • Parallel Operation
  • Remote On/Off
  • Wide Operating Temperature Range

Specifications

    General
  • Cooling: Conduction via 6mm baseplate
  • Current Share: Up to 3 power supplies can be connected in parallel sharing within 10%, total output power derates by 10%
  • Earth Leakage Current: <1.5 mA at 230 VAC
  • Efficiency: 80% typical
  • Hold Up Time: 10 ms min
  • Initial Set Accuracy: ±1% nominal
  • Input Current: 3 A max at 90 VAC (BCC200), 6 A max at 90 VAC (BCC400)
  • Input Frequency: 47-63 Hz
  • Input Protection: Internal T10 A/250 V fuse
  • Input Voltage: 90-264 VAC
  • Inrush Current: 60 A at 264 VAC +25 ºC cold start
  • Isolation: 3000 VAC Input to Output, 1500 VAC Input to Ground, 500 VAC Output to Ground
  • Line Regulation: ±0.5%
  • Load Regulation: See table
  • Minimum Load: No minimum load
  • MTBF: 160 kHrs to MIL-HDBK-217F at 25 ºC, GB
  • Operating Humidity: 20-95% RH, non-condensing. Units can be conformally coated for high humidity environments - add suffix ‘-E’
  • Operating Temperature: -20 ºC to +70 ºC, with baseplate maintained below +83 ºC utilizing system cooling, -40 ºC option available - add suffix ‘-L’ to model number
  • Output Power: See table
  • Output Voltage: See table
  • Output Voltage Trim: 60% to 110% Vnom
  • Overload Protection: 102-140% constant current limiting with auto recovery
  • Overtemperature Protection: Shuts down at +115 ºC baseplate temperature, recycle mains to reset
  • Overvoltage Protection: 105-140% Vnom (3.3 V version 130-166%)
  • Power Factor: >0.9
  • Remote On/Off: A logic ‘0’ on the Remote On/Off connection electronically disables the output
  • Remote Sense: Compensates for lead drops of up to 500 mV
  • Ripple & Noise: <1% pk-pk, 20 MHz bandwidth
  • Shock & Vibration: 2 g 10 min/1 cycle, 10 Hz to 500 Hz, 60 mins each axis
  • Storage Temperature: -40 ºC to +85 ºC
  • Switching Frequency: PWM 360 kHz typ, PFC 90 kHz typ
  • Temperature Coefficient: 0.05%/ºC

 

Applications

  • None Available

Aliases