Specifications

    General
  • Conducted Immunity: IEC61000-4-6 10 V/m, level 3; Perf Criteria B
  • Dips & Interruptions: IEC61000-4-11, 30% 500 ms, 60% 100 ms, 100 % 5000 ms; Perf Criteria A, A, C
  • Earth Leakage Current: 180 µA max at 132 VAC/60Hz; 300 µA max at 264 VAC/50Hz
  • Efficiency: Single output models:80% typical; Multi output models:75% typical
  • EFT/Burst: IEC61000-4-4, level 3; Perf Criteria B
  • Emissions: EN55022, level B conducted; EN55022, level B radiated
  • ESD Immunity: IEC61000-4-2, level 3; Perf Criteria B
  • Harmonic Currents: EN61000-3-2, class A
  • Hold Up Time: 10 ms min at low line
  • Input Current: 1.35 A max
  • Input Frequency: 47-63 Hz
  • Input Voltage: 90-264 VAC
  • Inrush Current: 30 A at 115 VAC or 60 A at 230 VAC at 25 °C cold start
  • Isolation: 4000 VAC Input to Output; 1500 VAC Input to Ground; 500 VAC Output to Ground
  • Line Regulation: ±1% max at full load for ±10% change in input
  • Load Regulation: ±5% max
  • Minimum Load: No minimum load required for single output models
  • MTBF: 100 kHrs at full load and 25°C ambient per MIL-HDBK-217F
  • Overcurrent Protection: 110-200% with auto recovery on all outputs
  • Overvoltage Protection: 112-132% with auto recovery on V1
  • Power Factor: 0.55 typical
  • Power Frequency Magnetic Fields: IEC61000-4-8 10 A/m, Perf Criteria B
  • Radiated Immunity: IEC61000-4-3 10 V/m, level 3; Perf Criteria B
  • Ripple & Noise: 2% pk-pk, 20MHz BW
  • Safety Approvals: UL60601-1, CSA C22.2 No. 601.1 per cUL; EN60601-1, CCC (PCM80)
  • Start Up Delay: 2 s max
  • Surge: IEC61000-4-5, level 3; Perf Criteria B
  • Switching Frequency: 64 kHz typical
  • Temperature: Operating:0°C to +70°C, derate from 100% load at 50°C to 50% load at +70°C; Storage:-40°C to +80°C
  • Temperature Coefficient: ±0.05% /°C
  • Transient Response: 5% max. deviation, 500 µs recovery time for a 50% load change
  • Voltage Flicker: EN61000-3-3 amendments 1 & 2

 

Applications

  • None Available

Aliases