Features
- Class I and II Construction
- Compact Size
- Convectioncooled
- DC Input Version Available (DCM Series)
- IT & Medical Approvals
- PoE Isolation Version Available (POE Series)
Specifications
- Cross Regulation: 2% on ECM40/60 only
- Earth Leakage Current: <125 µA at 115 VAC/60 Hz <210 µA at 230 VAC/50 Hz
- Hold Up Time: 16/75 ms min at 115/230 VAC
- Initial Set Accuracy: ±1.0% V1, ±5% V2, V3 & V4
- Input Current: 0.4 A max at 230 VAC
- Input Frequency: 47-63 Hz; 440 Hz*
- Input Protection: Internal T3.15 A, 250 V fuse in line and neutral
- Input Voltage: 90-264 VAC (120-370 VDC)
- Inrush Current: 40 A max at 230 VAC
- Line Regulation: ±0.5%
- Load Regulation: ±1% single output models;±3% V1, ±5% V2 & V3 ECM40/60 multi-output models.
- Output Voltage Trim: ±5% on 3.3 V & 5 V versions, ±10% on other single output models and V1 of multi-output models.
- Over/Undershoot: None at turn on/off
- Overload Protection: 110-150% on primary power limit,auto recovery
- Overvoltage Protection: 115-135% Vnom, recycle input to reset
- Peak Load: 120% for 100 ms ECM40/60
- Power Factor: EN61000-3-2
- Ripple & Noise: 1% pk-pk, 20 MHz bandwidth
- Short Circuit Protection: Trip and restart (hiccup mode)
- Start Up Delay: 1.5 s max
- Start Up Rise Time: 10 ms max
- Temperature: 0.05%/°C
- Transient Response: 4% max. deviation, recovery to within 1% in 500 µs for a 25% load change
Applications
- None Available
Aliases