AEH45US03 - XP Power AEH45US03 Power Supplies - Output Power Max: ...
Request Quote
For Price
- Part Number:
- AEH45US03
- Model Number:
- AEH45US03
- Make:
- XP POWER
- Lead Time:
- Available
- Qty In Stock:
- Available
XP Power AEH45US03 Power Supplies - Output Power Max: 26 W Voltage Nom: 3.3 V AEH45 Series Simple Type: Power Supply
For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.
Features
- 0 °C to +70 °C Operating Temperature
- Efficiency up to 80%
- Non-standard Connectors Available
- Non-standard Outputs Available
- Output Voltages from 2.5 V to 48 V
- Single & Multiple Output Versions
- Universal Input
Specifications
- Conducted Immunity: EN61000-4-6, level 2 Perf Criteria A
- Dips & Interruptions: EN61000-4-11 30% 10 ms, 60% 100 ms, 100% 5000 ms; Perf Criteria A, B, B
- Earth Leakage Current: <0.5 mA max at 115 VAC/60 Hz; <0.75 mA max at 230 VAC/50 Hz
- Efficiency: Up to 80%
- EFT/Burst: EN61000-4-4, level 2 Perf Criteria A
- Emissions: EN55022 level B, conducted and radiated
- ESD Immunity: EN61000-4-2, level 2 Perf Criteria A
- Harmonic Currents: EN61000-3-2, Class A
- Hold Up Time: 16 ms min (>50 ms AEH130)
- Initial Set Accuracy: 5%
- Input Current: 1.5/0.7 A, at 115/230 VAC
- Input Frequency: 47-63 Hz
- Input Voltage: 90-264 VAC
- Inrush Current: 30 A max at 230 VAC
- Isolation: 3000 VAC Input to Output; 1500 VAC Input to Ground; 500 VAC Output to Ground
- MTBF: 100 kHrs per MIL-HDBK-217F
- Operating Humidity: 5-95% RH, non-condensing
- Operating Temperature: 0°C to +70°C, derate linearly from 100% load at +40°C to 50% load at +70°C
- Overload Protection: Output 1 only 110-150% of nominal
- Overvoltage Protection: 112-132% Vnom, auto reset
- Power Factor: EN61000-3-2 class A
- Radiated Immunity: EN61000-4-3, level 3 Perf Criteria A
- Ripple & Noise: 2% pk-pk for outputs =3.3 V; 1% pk-pk for all other outputs; 20 MHz BW
- Safety Approvals: EN60950-1, UL60950-1, CSA C22.2 No. 950 per cUL, CE Mark
- Start Up Delay: 2 s max
- Storage Temperature: -40°C to +85°C
- Surge: EN61000-4-5, level 3 Perf Criteria A
- Switching Frequency: 67-83 kHz for AEH45; 58 kHz typical for AEH80; 53-76 kHz for AEH130
- Temperature Coefficient: ±0.04%/°C max
- Transient Response: 4% max deviation, recovery to within 1% in 4 ms for a 50% load change
- Vibration: 2 g on 3 axes
- Voltage Flicker: EN61000-3-2
Applications
- None Available
Aliases
- None Available